Category: |
Alat Kesehatan |
Excellent Performance
- Up to 200 T/H
- First result in ≥ 12 min (assay dependent)
Compact & Convenient
- Footprint 0.67 m2, patented technology for highly integrated and simplified design
- Batch/random/STAT mode available
- Integrated control panel with machine, all consumable loading in real time
Innovative Design
- Incubation, washing and detection all-in-one, detection efficiency improved
- Using automatic intelligent control technology, low instrument failure rate
- 100+ patented technologies, 100% self-developed
Open system
- Multiple options: 4 different models (AE, AP, HRP, ABEI)
- Compatible with immunological reagents and instruments with different parameters and reaction modes
Technical Specification
Overview
Principle : Enzymatic chemiluminescence or direct CLIA
Throughput : 200 T/H
Time to First Result : ≥ 12 min (assay dependent)
Walk away capacity : 3 hrs
Accessories & Consumables
Assay Cup Loading : 500 cups, continuous loading and offloading
Wash Buffer : 10 L/bottle
Solid Waste : 500 assay cups per container
Liquid Waste : 1 barrel, for collecting waste liquid of the whole machine
Substrate Loading : 2 bottles to load continuously during test
Physical Information
Construction : Desktop
Weight : ≤129 kg
Sample Assembly
Sample Feeder : By sample racks
Sample Capacity : 60 positions
Sample Type : Serum/Plasma/Urine/Whole blood
Sample Probe : Single steel probe for both sample & reagent
Sample Volume : 10~150 μL
Probe Detection : Clot, bubble & liquid level detection
Sample Tube : Optional
Automatic dilution function
Support multiple barcode reading methods
Reagent Assembly
Reagent Feeder : By reagent Disks
Reagent Capacity : 25 positions
Cooling System : 2~8oC
Anti-evaporation Control : Self-sealing
Reagent Mixing : Non-touch rotary mixing for magnetic particles
Reagent Volume : 10~200 μL
Reagent Type : 100% ready-to-use liquid reagents
Calibration Mode : Optional
Operation Environment
Operating Temperature : 10~30 oC
Humidity : ≦ 85% (noncondensing)
Altitude : ≤ 4000 m
Reaction System
Reaction Volume/Test : ≤ 400 μL
Reaction Disk : 90 positions
Reaction Temperature : 37±0.3°C
Reaction Time : Depending on assays
Reaction Mixing : Non-touch vortex mixing
Power information
Power Requirements : 100-240 V, 50/60 Hz
Power Input : 1000 VA
Dimension : 1000(W)*670(D)*640(H)mm(control panel included)
Brosur AUTOMATIC CHEMILUMINESCENCE IMMUNOASSAY ANALYZER
Ruko Arcadia Grande, Jl. Boulevard Raya Gading Serpong No.19 Blok D / 18, Klp. Dua, Kec. Klp. Dua, Kabupaten Tangerang,Banten 15810
busdev@fulonapharma.com
+62 21 5053 7888
+62 821 1273 9393